The SituationA homeowner in Cutler Bay (33157) returned after a storm to find the opener dead. Wall button did nothing; ceiling outlet had power. Remote LEDs blinked once, then silence.
On-Site Diagnosis
Surge event: scorch marks on the logic board and a failed MOV protector.
Motor windings passed resistance checks; board failure isolated.
Photo-eyes aligned and functional; limit settings intact.
No upstream surge protection and no battery backup.
What We Did
Installed a new logic/control board matched to the opener model.
Added an inline surge protector and recommended a whole-home protector via licensed electrician.
Tested UL 325 sensors, recalibrated force/limits, and updated remote codes.
Offered battery backup module to cover future outages.
Documented pre/post voltage readings and provided a storm-readiness checklist.
Parts & Specs
OEM logic board; inline surge module; fresh remote codes; optional backup battery.
Compliance & Safety
UL 325 verification completed; homeowners briefed on safe manual release protocol.
OutcomeOpener revived with clean, consistent operation. With surge protection installed, the system is far less vulnerable to summer lightning.